The RIDA®SMART APP is a complete new evaluation technology for the quantification of mycotoxins. This technology evaluates lateral flow tests (LFDs), which are used for immunochromatographic analysis of mycotoxins. The app provides reliable and accurate results, which can be forwarded via e-mail or easily sent to any supported printer. The app represents a more inexpensive, easier and faster alternative to conventional LFD reading devices.
Unleash Your Potential - Namagunga Girls Coding Club
Mycotoxin Analysis in your hand – RIDA®SMART APP
1. RIDA®
SMART APP
Mycotoxin analysis in your hand
RIDA®
SMART APP – the next generation of rapid mycotoxins analyzers
Ronald Niemeijer, Director Global Marketing, R-Biopharm AG
2. R-Biopharm Group
RIDA®
SMART APP
RIDA®
SMART APP
Rapid mycotoxin testing means not just fast results……
It also means to obtain those results
on-site, basically at any place at any time.
3. R-Biopharm Group
RIDA®
SMART APP
RIDA®
SMART APP
Lateral flow based mycotoxin tests are the method of
choice to make those rapid decisions……
Yet until now measurement is
not really on-site
(but typically in a laboratory)
• Fast and easy sample preparation and test execution
• No specialist skills required
• No handling with hazardous mycotoxin standards
• Quantitative results analysis with reader
Advantages:
5. R-Biopharm Group
RIDA®
SMART APP
RIDA®
SMART APP
•Use a Nexus 6 and NEXUS 6P (V1.2) or higher from Google
or MotoX Pro from Motorola smartphone
•Buy your RIDA®
SMART APP voucher at R-Biopharm
•Download the RIDA®
SMART APP (QR code on voucher)
•Register and activate your voucher: http://app.r-biopharm.com
How does that work?
6. R-Biopharm Group
RIDA®
SMART APP
RIDA®
SMART APP
•Scan the QR-Code on
the voucher.
•Complete the registration
to install
•After installation activate
the app (voucher code)
•Your RIDA®
SMART APP is
now ready for use!
Installation of the RIDA®
SMART APP
8. R-Biopharm Group
RIDA®
SMART APP
RIDA®
SMART APP
Test
•Follow the instructions for
use of the RIDA®
QUICK
mycotoxin tests for sample
preparation and testing
• Place the cover over the lateral
flow device
• Each box of the RIDA®
QUICK
mycotoxin test comes with it’s
own cover
10. R-Biopharm Group
RIDA®
SMART APP
RIDA®
SMART APP
Scan
•Hover the smartphone over the lateral flow device, so the frame
and the cover are aligned
•Adjust to focus and press the camera button
•That’s it!
The app will calculate the result…
11. R-Biopharm Group
RIDA®
SMART APP
RIDA®
SMART APP
Scan
•Results are available within a few
seconds
•All results are stored within the
app on your smartphone
•Or you can send the results…
12. R-Biopharm Group
RIDA®
SMART APP
RIDA®
SMART APP
Send
•You can send the results
immediately by email
(if you have internet access)
•Or send the results later by
Wi-Fi or Bluetooth –
e.g. to a network printer
•You can also (re-)send stored
results from the RIDA®
SMART APP
database
13. R-Biopharm Group
RIDA®
SMART APP
RIDA®
SMART APP
Send
•Any technical questions about
the result you got?
•Do you need technical
assistance?
•Send the raw data to our local
technical support representative to
help you out
(You will need internet access for this)
14. R-Biopharm Group
RIDA®
SMART APP
RIDA®
SMART APP
More questions?
•Technical information is
available online: download the
manual, watch the
RIDA®
SMART APP video or get
the latest news updates from
R-Biopharm….
15. R-Biopharm Group
RIDA®
SMART APP
RIDA®
SMART APP
Yes, one more question – Does it work?
•We have extensively validated the performance of the
RIDA®
SMART APP. For example the effect of light conditions:
16. R-Biopharm Group
RIDA®
SMART APP
RIDA®
SMART APP
Yes, one more question – Does it work?
•Or the inter-“reader” (smartphone) variation – the same sample was
tested 20 times with 9 different smartphones:
3.8
3.9
4.0
4.1
4.2
4.3
4.4
4.5
1 2 3 4 5 6 7 8 9
Value
Reader
Reader 1 2 3 4 5 6 7 8 9
mean 4.38 4.44 4.29 4.33 4.05 4.39 4.24 4.32 4.38
SD 0.24 0.16 0.19 0.17 0.21 0.20 0.23 0.18 0.18
CV % 5.43 % 3.52 % 4.51 % 4.02 % 5.27 % 4.49 % 5.36 % 4.09 % 4.12 %
17. R-Biopharm Group
RIDA®
SMART APP
RIDA®
SMART APP
Yes, one more question – Does it work?
•And we validated the RIDA®
SMART APP using Trilogy certified
mycotoxin reference materials. Here are some data for aflatoxin
(compared to the RIDA®
QUICK SCAN reader):
Trilogy Reference Material Reference value Results
RIDA®
QUICK SCAN RIDA®
SMART APP
AC-215 Blank <4 µg/kg <4 µg/kg
AC-285 5,9 µg/kg 4.5 µg/kg 5.2 µg/kg
AC-2203 11,1 µg/kg 13,2 µg/kg 10,8 µg/kg
AC-286 20,2 µg/kg 23,4 µg/kg 20,5 µg/kg
AC-290 32,2 µg/kg 26,7 µg/kg 26,1 µg/kg
18. R-Biopharm Group
RIDA®
SMART APP
RIDA®
SMART APP
So these are both good lateral flow readers.
But what is the difference between both?
With the RIDA®
SMART APP you can:
• Read and evaluate mycotoxin tests anytime, anywhere
• Send and print results - online from any place
• Get (online) access to technical support
•You could even call us